Line Lock Phase Adjustment Potentiometer - Honeywell L Serie Guia Del Usuario

Ocultar thumbs Ver también para L Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
Line Lock Phase Adjustment
Potentiometer
When the camera is in Line lock mode, it is possible to
adjust the point on the AC cycle at which the camera
triggers. This feature allows for synchronization of cameras
that are connected to different phases.
The V-PHASE adjustment potentiometer allows the line
lock phase trigger point to be adjusted by 270°. Rotating
the potentiometer clockwise advances the trigger point and
turning it counterclockwise retards the trigger point. If all
cameras in a system are on the same phase then no line
lock phase adjustment should be made.
Rev 2
V-PH
VID EO
CLASS 2 ONLY
IR IS
V-PH
LEVEL
PWR
VSD
AES
AI
OFF
BLC
OFF
AGC
IN T
LL
D C
6
Low Voltage version shown
INT
LL
= ON
L EG E ND
= OFF
G-113078-002
02/07

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hcm574lHcm384lHcm584lxHcm585lxHcm404lxHcm405lx

Tabla de contenido