1. GENERAL
1.1 Carefully read the following important in-
formation regarding installation safety and
maintenance. Keep this information booklet ac-
cessible for further consultations.
The appliance has been designed as a suction
version (external exhaust) or as a filter version
(internal air recycle) cooker hood.

2. INSTALLATION INSTRUCTIONS

2.1 Electric Connection
The appliance has been manufactured as a class
II, therefore no earth cable is necessary.
The connection to the mains is carried out as fol-
lows:
BROWN
=
L
line
BLUE
=
N neutral
If not provided, connect a plug for the electrical
load indicated on the description label. Where a
plug is provided, the cooker hood must be installed
in order that the plug is easily accessible.
An omnipolar switch with a minimum aperture of
3mm between contacts, in line with the electrical
load and local standards, must be placed between
the appliance and the network in the case of direct
connection to the electrical network.
2.2 The appliance must be installed at a mini-
mum height of 650 mm from an electric
cooker stove, from gas or combined cooker
stoves.
If a connection tube composed of two parts
is used, the upper part must be placed out-
side the lower part.
Do not connect the cooker hood exhaust to
the same conductor used to circulate hot air
or for evacuating fumes from other appli-
ances generated by other than an electrical
source.
2.3 Mounting the cooker hood to the wall
Drill holes A-B-C-D according to indications quoted
in (fig. 3).
Use screws and screw anchors suitable for wall
(e.g. reinforced cement, plasterboard) for the
mounting of the cooker hood.
Where screws and screw anchors are supplied
ensure that they are suitable for the type of wall
where the cooker hood is to be mounted.
Lock in the flange connector Y to the cooker hood
(fig. 2).
6
Affix the bracket Z to the wall via the drill holes A
(fig.4).
Hang the cooker hood on the wall using the drill
holes C (fig.3).
Fasten the cooker hood using the fastening drill
holes D (fig.3).
2.4 Suction Version
Connect the flange Y to the discharge opening with
a connecting tube (do not carry out for filter ver-
sion).
Thread the upper connector E to the inside of the
lower connector F; hang the two connectors in-
serting them vertically on the cooker hood locking
the lower connector F to the wall using the drill
holes B (fig. 3), unthread the upper connector E
towards the top, locking it in with the appropriate
screws in the drill holes G of the bracket Z (fig. 2)
previously affixed to the wall via the drill holes A
(fig. 3).
In order to transform your cooker hood from suc-
tion version to filter version, ask your local retailer
for active carbon filters and then carry out instruc-
tions for mounting filter version cooker hood.
2.5 Filter Version
Install the cooker hood and the two connectors as
described in the paragraph mounting the suction
version cooker hood.
To mount the filter connector refer to instructions
included in the kit.
If the kit is not supplied, then order the kit as an
accessory from your local dealer.
The filters must be applied to the suction kit located
inside the cooker hood and centred by rotating at
90 degrees until locked in.
The air is replaced in the environment via the eye-
lets impressed on the connector E.

3. USE AND MAINTENANCE

3.1 It is recommended to operate the appliance prior
to cooking.
It is recommended to leave the appliance in opera-
tion for 15 minutes after cooking is terminated in
order to completely eliminate cooking vapours and
odours.
The proper function of the cooker hood is condi-
tioned by the regularity of the maintenance opera-
tions, in particular, the active carbon filter.
3.2 The anti-grease filters capture the grease par-
ticles suspended in the air, and are therefore sub-
ject to clogging according to the frequency of the
use of the appliance.
In order to prevent fire hazard, it is recommendable
to clean the filter at a maximum of 2 months by
TW13