Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INTERFACE TELEFONICO
INTERFACE TELEFONICO
Here are a couple of practical examples of how to program the Interface installation parameters:

PROGRAMMING EXAMPLE 1

To program the Relay Timing; take the following steps:
1- Unhook the telephone handset you are going to program the Interface from.
2- Press three times the '#' key. The PRG LED will light up and the
stops.
3- Enter the digit corresponding to the parameter you wish to program.
In this example it would be 2
4- Key in the new parameter value. To introduce this value, consult the table on the
previous page, where:
If you want an opening time of 5 seconds, select an N value, so that:
The maximum door open timing we can set corresponds to the maximum N:
5- Press '#' again to exit programming mode or wait 30 seconds without pressing any keys.
To program the Open Door Timing or Ring Pattern, proceed in the same way and assign N the
value needed to obtain the desired timing.
PROGRAMMING EXAMPLE 2
Let's see how to program the ADS number:
This only needs to be done if you have Telephone Interface Ref. 1088.
- Proceed with the first 2 steps as in the example above. In step 3, key in 0, (digit corresponding to the
ADS Number parameter as appears in the table on the previous page).
- Step 4, enter the parameter value (ADS telephone nº between 1 and 199)
You must enter the same number as the FERMAX electronic door control system .
- Press '#' to exit programming mode.
You also exit programming mode after 30 seconds without pressing any key.
t = 5 seconds
N = 200
N = t*4
t =
N / 4
dialling
tone
N = 20
50 seconds
13