Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 129
EN
Maintenance

Function test

Recommendation: regularly perform the function test described
below.
Task
Check LED
.
Press the
<TEST>
button.
Press the
<TEST> button
for 1 second.
Maintenance
Have the maintenance work described below carried out every
2 years by a skilled person.
• Clean the basket filter.
• Clean and descale the trap.
44
Result
Control unit shows the
current settings.
The solenoid valve
opens and water
flows until the set
flush volume has
been reached.
Action
If LED
flashing, replace the
battery. → See
"Replacing the
battery", page 45.
Replace the battery
if no LED lights up.
→ See "Replacing
the battery",
page 45.
If water does not
flow → see
"Rectifying
malfunctions",
page 42.
9007206954690955-1 © 02-2021
970.123.00.0(00)
is

Publicidad

Tabla de contenido
loading

Tabla de contenido