Sound Pressure
This unit has a sound pressure level at the operator's
ear of 83.1 dBA, with an Uncertainty Value (K) of 3
dBA.
The sound pressure level was determined according
to the procedures outlined in EN ISO 11201.
Sound Power
This unit has a guaranteed sound power level of 96
dBA, which includes an Uncertainty Value (K) of 1.02
dBA.
The sound power level was determined according to
the procedures outlined in EN ISO 11094.
Hand/Arm Vibration
Measured vibration level for right hand = 2.19 m/s
2
Measured vibration level for left hand = 2.06 m/s
2
Uncertainty Value (K) = 1.5 m/s
2
The measured values were determined according to
the procedures outlined in EN ISO 20643.
Important:
The vibration emission during actual
use of the power tool can differ from the declared
total value depending on the way the tool is
used. The operator should take safety measures
based on an estimation of exposure in the actual
conditions of use.
4