D. CHARGING
Before installing the new battery, remember to charge it completely.
Remember to charge the battery everytime the charge is below 12,8V.
ATTENTION:
1. Use only for charging battery chargers specific for Lithium-Iron-Phosphate
(LiFePO4) batteries.
2. Follow the parameters indicated below for the charge powers:
MODEL
GK-ATHBL-0003
GK-ATHBL-0004
Charge the battery with a current less than the maximum specified in the table.
3. To guarantee maximum operational battery life, do not charge at the
maximum current for more than 30 minutes, even if the battery is completely
discharged.
4. The charge voltage must never exceed 15V.
5. If the battery heats up excessively, stop charging and wait until it has cooled
down before continuing with charging.
6. After charging, wait at least once hour before checking the voltage.
7. If the voltage is below 12.8V the battery must be charged further.
5/6 bars illuminated - Battery in good
operating conditions.
3/4 bars illuminated - Battery needs to
be recharged.
1/2 bars illuminated - Battery in abnormal
operating conditions; recharging and
recovery are not guaranteed.
CHARGE VOLTAGE
STANDARD
MAXIMUM
14.4V
14.6V
14.4V
14.6V
7
CHARGE CURRENT
STANDARD
MAXIMUM
LESS THAN
LESS THAN
1 HOUR
30 MINUTES
2.5A
2A
5A
4A
EN