3 STOVE OPERATION
3.1 STARTING THE STOVE
Before every ignition, be sure that burning pot is
completely empty and properly positioned in its
seat.
To start the stove hold the
seconds.
stage until remaining on steady when the stove has
started.
Automatic stove ignition: the stove comes with an
automatic device that starts the pellet stove without
automatic ignition system is not working correctly.
odours or smoke may be generated, caused by
evaporation or drying of certain materials used.
This phenomenon will gradually disappear.
The room should be well ventilated when starting
3.2 MODIFYING THE PARAMETERS
as described.
even when the stove is switched off or unplugged
from the power supply.
3.3 SWITCHING OFF
To switch the stove off hold the
To start the stove again it's recommended to wait
for the stove to cool down completely.
The stove should only be switched off following the
procedure described above. Never switch the stove
off by unplugging it from the power supply.
3.4 OPERATION WITH ROOM
THERMOSTAT
thermostat (or timer thermostat), the installer must
alternatively modulates output (that is, the stove
attempts to maintain the desired temperature
while minimising fuel consumption) when reaching
the set water temperature.
The stove switches on again automatically when
the temperature falls below the value set on the
button for several
3.5 OPERATION WITH ROOM PROBE ON
button for a
3.6 OPERATION IN COMBINATION WITH A
panel.
The stove will go off automatically even in the
case the water temperature keeps growing
notwithstanding the modulation mode. In this case
the stove will ignite only if the difference between
suggest that you select a high water temperature
THE BOILER
programmed mode.
output according to the room temperature read
by the probe on the boiler (that is, the boiler
attempts to maintain the desired temperature
while minimising fuel consumption).
under submenu [7] of the setup menu
rather than modulating its output, switches off
when reaching the set temperature, and switches
on again when the room temperature falls below
the delta set in submenu [7] of the setup menu
The desired room temperature can be set in
temperature menu
.
6]
Submenu [
of the setup menu
used to set the desired water outlet temperature
(the best temperature for the heating system
system installer).
STORAGE TANK
For operation in combination with a storage tank,
depending on whether the storage tank is with or
without a coil inside.
The boiler is controlled based on the temperature
read by the probe in the storage tank.
When reaching the storage tank temperature set
in the temperature menu
setup menu
.
The frost protection function can also be set in this
, the boiler
.
can be
[8]
of the
21