Decrease
AC wave shape
Frequency
The demagnetisation cycle is started by a long press on the process icon
Compensation mode operating advice:
1 - Check the magnetisation value of the part with the field meter (not provided).
2 - Carry out the assembly of the cables around the part to be welded connected to the equipment and adjust the
demagnetisation cycle.
3 - Start the demagnetisation cycle and wait for the end of the cycle signalled by the animation to the HMI.
COMPENSATION mode :
This mode allows to locally cancel the magnetism of the part during welding by injecting a reverse magnetic field.
EASY Mode
Settings
Degauss force
Polarity
The demagnetisation cycle is started by a long press on the process icon
the remote control is connected, the polarity is adjusted to it.
EXPERT & ADVANCED mode
Settings
Growth
Saturation current
Stage
Decrease
The demagnetisation cycle is started by a long press on the process icon
the remote control is connected, the polarity is adjusted to it.
DEGAUSS
Duration of compensation current decrease. It is advisable to set the time so that
the decrease lasts at least 30 AC current periods.
0s -
Examples:
30min
F = 1 Hz, Decrease = 30 s,
F = 10 Hz, Decrease = 3 s,
F = 0.1 Hz, Decrease = 05:00 (or 300 s).
-
AC waveform.
Hz
Saturation current frequency
Unit
Pre-set compensation values depending on the magnetic induction of the work-
1 - 10
pieces to be welded in manual mode (ON/OFF).
+ / -
Compensation current polarity.
Unit
min
Current growth time
A
Compensation current in A
Duration of saturation current stage.
min
is used to maintain the current step as long as the cycle is ON.
min
Duration of the decrease of the magnetic reset current
or with the remote control (ON / OFF).
or with the remote control (ON / OFF). If
or with the remote control (ON / OFF). If