Compensation mode usage advice:
1 - Check the magnetisation value of the part with the champmeter.
2 - Fit the cables around the workpiece connected to the material and adjust the demagnetisation cycle (see: Help to
determine the number of turns and the current setting).
3 - Set the current to minimum and start the cycle (ON).
4 - Gradually increase the current until the measured field strength is zero or close to 0 (Expert or Advanced mode) or
modify the Compensation Force if necessary (Easy mode).
If the field value increases, repeat the process by reversing the polarity (+/-).
Additional degauss parameters (accessible in the process menu) :
Settings
Demagnetisation
Compensation
Rupture voltage
ERROR MESSAGE, ANOMALIES, CAUSES AND SOLUTIONS
This device integrates a default management system. In the event of a failure, the following error messages may appear:
ERROR CODE
No cable connected
Demagnetising voltage too
high
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
12
DEGAUSS
Unit
-
Selecting the Total Demagnetisation mode
-
Selecting the Compensation mode
Breakdown voltage of the demagnetisation
cycle in case of undersized or damaged cables.
V
In EASY display mode, the breakdown voltage
is set to 10 V.
CAUSES
The demagnetising cables are not
connected.
The voltage at the output termi-
nals of the machine is too high.
Availability
(Display mode)
Easy / Expert / Advanced
Expert / Advanced
SOLUTIONS
Check the connection of the cables both on the
machine and between them.
Check that the cables are not damaged.
Check that the cables are not damaged.
Check that the cables are not undersized in
relation to the set current (consider 12 A per
mm² cable cross-section).