Technical Information
Logic Interconnections

Controller-to-Pump-Connection

To connect the controller to the pump an appropriate
interconnection cable must be prepared to connect the J9 terminal
board of the controller with the pump connector.
The following figure shows the pump output connector configuration
where pins:
Figure 13
248/280
Pins A-F = pump temperature sensor
Pins B-C-D = 54 Vac 3-phase output to pump motor stator
Pin E = ground.
Controller-to-pump cable