Descargar Imprimir esta página

Kohler K-1035-H2 Diagrama De Instalación página 2

Ocultar thumbs Ver también para K-1035-H2:

Publicidad

Idiomas disponibles

Idiomas disponibles

15-11/16"
(39.8cm)
31-7/8"
(81cm)
3-1/4"
(8.3cm)
10-1/4"
(26cm)
1-1/2"
(3.8cm)
2-1/4"
(5.7cm)
Product Information
Applicable product:
Left outlet
Right outlet
Accessories/hardware:
Tower
Alcove enclosure
Fixture*:
basin area
Bathing well
44" (111.8cm) x
36" (91.4cm)
water depth
To overflow
8-1/4" (21cm)
* Approximate measurements for comparison only.
**37 gallon (140L) min. required for system operation.
Varaiable-speed
2 HP
pump
Heater
4 kW
Minimum access panel for pump/control:
29" (73.7cm) W x 14" (35.6cm) H
Required Electrical Service (2 required)
Two dedicated 240 V electrical circuits are required, one for
the pump/control and one for the heater, each protected with
a Class A Ground-Fault Circuit-Interrupter (GFCI) or
Earth-Leakage Circuit-Breaker (ELCB):
Pump/control
220-240 V, 20 A, 50/60 Hz
Heater
220-240 V, 20 A, 50/60 Hz
1032120-1-A
4" (10.2cm)
54" (137.2cm)
58" (147.3cm)
3/8" (1cm)
2-7/8" (7.3cm)
3" (7.6cm)
K-1035-H2
shown
K-1036-H2
not shown
K-1030
required
K-5161-L
required
top area
45" (114.3cm) x
37" (94cm)
capacity
43 gal. (162.7L)
220-240
50/60
V
Hz
220-240
50/60
V
Hz
required
9-3/4"
(24.8cm)
44-3/8"
(112.7cm)
*KEYPAD 58"
(147.3cm) TO 60"
(152.4cm) FROM
FLOOR OF BATH)
TOWER STUD (2X6)
OPENING
PUMP/CONTROL
ACCESS (ALLOW
FOR PROTRUSION)
16"
13"
(40.6cm)
(33cm)
10-3/4" (27.3cm)
Notes
Refer to the installation instructions included with this fixture
before beginning installation.
Stud placement is critical. Carefully follow installation instructions
for stud pocket placement.
Locate the keypad within reach of the control box. An 8' (2.4m)
cable is included.
Enclose the top of the unit to retain heat and contain water spray.
This unit is not designed for steam applications, and may not
perform satisfactorily as a steam unit.
weight
110 lbs.
No changes in measurements are necessary if the unit is connected
(50kg)
with the drain illustrated (K-7160-AF or K-7160M-AF).
Blind installations on the backside require a 1-7/8" (4.8cm) to
2-1/2" (6.4cm) diameter hole for the keypad nut.
6 A
15 A
2
54" (137.2cm)
*3/8" D. (1cm)
HOLE (DRILL
FIRST)
CUT-OUT DETAIL FOR
DECK INSTALLATION
*1-5/8" D. (4.1cm) HOLE
(DRILL SECOND)
TOWER PIPING
ATTACHES HERE
13" (33cm)
1-1/2" (3.8cm)
1-1/2" I.P .S. THR'D
35-7/8"
(91.1cm)
51-1/4"
(130.2cm) R.
19"
(48.3cm)
1-1/2" O.D.
Kohler Co.

Publicidad

loading

Este manual también es adecuado para:

K-1036-h2