Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Tau Controller
24 V input or the push-to-start (PTS) switch on the tool.
Todos – The tool trigger and the PTS switch must be activated in order to start the tool.
Palanca – Only the trigger on the tool can start the tool.
PTS – Only the push-to-start switch on the tool can start the tool.
None – Neither the tool trigger nor the tool push-to-start switch can start the tool.
Temporizador faro – Sets the time the pistol tool headlights remain on, in seconds, after the
trigger is pressed.
Cal de torque – This is the specific torque calibration value for the tool. Enter a new value after
performing a lab certification. The Torque Cal should not deviate from the Nominal Cal value
by more than 20%.
Odómetro – Cannot be reset. Indicates the total number of OK tightening cycles the attached
tool has performed over its lifetime.
Contador MP – Causes the preventive maintenance LED to illuminate (on front panel and tool)
when this value exceeds the PM Threshold.
Límit PM – When the PM Counter in the tool exceeds this threshold, the preventive
maintenance LED on the front panel illuminates indicating it is time to perform maintenance
on the attached tool.
Reset PM – Select YES to reset the PM Counter back to zero.
Press a keypad button to save changes and return to the Run screen.

2.7.1.3 Velocidad

Velocidad programs the tool's free running and downshift speeds functions.
Velocidad Screens
Modo Downshift – Selects the type of spindle inertia control toward the end of a tightening
cycle.
Desconectado – Does not reduce the speed of the motor.
Manual – Reduces the tool speed to a specific value (Downshift Velocidad) when a specific
torque value (Downshift Torque) is achieved during the tightening cycle. Velocidad units are
RPM, Torque is in torque units.
Programación
Options Screens
Press the Velocidad button on the keypad to
select.
Use the left or right arrow keys to select a job
to program.
Velocidad – The velocity of the output of the
tool before any Downshift Mode activates.
Units are RPM. Required to run the tool. Must
be greater than 0.
Aceleración - The rate the tool achieves
Velocidad in RPM/s (revolutions per minute
per second) required to run the tool. The rate
should be greater than 1000 RPM/s.
15

Publicidad

Tabla de contenido
loading