ADA HIGH VOLTAGE WIRING INSTRUCTIONS FOR DOUBLE BLOWER RANGE HOODS WITH
For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service
disconnecting means to prevent power from being switched on accidentally. Installation work and electrical wiring
must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction codes and standards. Also, it is recommended to wear safety glasses and gloves.
A
CCESS TO RANGE HOOD CONTROL PANEL CONNECTIONS
Remove both filters from the hood and set them aside.
Remove both side fillers by removing the 3 screws holding each
one of them. Slide each one towards the center of the hood and
tilt it up to remove it completely. Set the fillers and screws aside.
Using a 11/32" nutdriver or socket, remove both lock nuts
retaining the flange of each blower cover plate (shaded parts
on illustration at right) to the inner back of hood (see insets).
Remove all cover plate retaining screws (10 screws), then set
both blower covers along with their screws and nut aside.
5
10
9
BACK OF HOOD
HO0280
ROCKER SWITCH CONTROL
4
3
6
2
8
1
7
L
OCK NUTS
WARNING
!
Locate the small plates on both left and right inner side ot the
hood (shaded part in illustration below). Use thin sheet metal
snips to split these plates.
Be careful not to kink the range hood side panels while
splitting the plates.
NOTES: 1. The plates are for shipping purpose only, there is no
need to reinstall them.
2. Blower not shown on illustration to ease
understanding.
HR0213
Remove and set aside the 4 front screws retaining the inner front
plate to the hood.
HD1103
Fold back the inner front plate to access to the hood control
connections. Carefully cut-off the tie wrap retaining wires
together.
HD1104
1
CAUTION
Screw locations
T
IE WRAP
99045893B