Function F5 - Activate continuous operation
Button
Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F5 Function select by turning the ring
• Start F5 - Activate continuous operation
=> Confirm by simultaneously pressing the - / + buttons.
- Press Start/Stop button of digital controller.
- Press - button of digital controller.
- Press + button of digital controller.
=> Pressing the - / + buttons simultaneously starts the continuous operation.
False entry => abort menu.
Caution: Risk of scalding. The 42 °C setted safety stop is
deactivated.
Abort of the function after 15 minutes (after that cold water runs for a minute) or
prematurely by operating the digital controller as well as a the transceiver (no
cold water running).
Fault
No function
Segment flashes 1x white
Segment flashes green
Segment flashes 1x yellow
Segment flashes 1x red
Disposal instructions
This category of device does not belong in the domestic waste, but must be disposed of separately in accordance
with the relevant local national regulations.
Dispose of batteries in accordance with national regulations.
Cause
• No voltage supply
• Digital controller not ready or registered
• Digital controller out of range
• Radio interference
Obstacle in transmission path
• 1x: Batteries digital controller almost empty
• 2x and water pulses: Battery functional
unit almost empty
• 2x without water pulses: Battery
functional unit not connected or empty
• 3x: Temperature too high
• Software malfunction
• Hard- or software malfunction
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 5x.
Illuminated ring flashes green 1x.
Segment of illuminated ring
flashes blue 1x.
Segment of illuminated ring
flashes blue 1x.
Segment of illuminated ring
flashes blue 1x.
Illuminated ring flashes cyan 3x.
Illuminated ring flashes violet 3x.
Illuminated ring flashes cyan 3x.
Remedy
- Connect voltage supply
- Register digital controller
- Reduce distance or use special accessory
transceiver (order no 36 356)
- Deactivate potential source of interference and
check function again => If positive reconfigure
the interference source (eg wireless router)
- Rectify the fault
- Check installation or replace unit battery
- Check installation or replace unit battery
- Connect plug in-connector battery or replace
battery
- Wait until feeler gauge is cooling down
- Calibrate functional unit
- Switch off the voltage supply and consult a
specialist installer or the GROHE Service
Hotline
- Switch off the voltage supply and consult a
specialist installer or return the product to
GROHE