Product Information (cont.)
NOTICE: Provide unrestricted service access to the pump. You must provide access for servicing the
pump, heater and control. The access must be located immediately next to the pump. Refer to the Design
Guide section of this manual.
Electrical Requirements
The installation must have two Ground-Fault Circuit-Interrupters (GFCI) or Earth-Leakage Circuit-Breakers
(ELCB). The GFCI or ELCB protects against line-to-ground shock hazard. Use a 220-240 V, 20 A, 50/60 Hz
dedicated service for the pump and control. Use a separate 220-240 V, 20 A, 50/60 Hz dedicated service for
the heater.
Kohler Co.
3
1030218-2-A