Technical information:
Torque capacity: 20-50-80 cNm
Accuracy (from 10% to 100% of the nominal torque): ±0.5% FSD (Full Scale Deviation)
Overload protection at 120% of nominal capacity
Integrated amplifier electronics
Torque sensor direction: Clockwise
Stability of Zero offset with temperature: < ±0.1% FSD/°C
Bridge resistance: 1000 ohm
Operating humidity: 50% non-condensing
Operating temperature: 5 to 40°C
12/2018
Device
DSTxs 20
DSTxs 50
DSTxs 80
EN
Torque Capacity
2 – 20 cNm
5 – 50 cNm
8 – 80 cNm
7 / 160
Product Instructions
Overload torque
24 cNm
60 cNm
96 cNm