4
Mounting
5
Electrical installation
8025684.9RH / 15.01.2021 | SICK
Subject to change without notice
WTF26x-xxxxxx30
1
2
4
3
BluePilot blue: sensing range display
1
Press-turn element / Potentiometer / Teach-Button: adjusting the sensing range
2
LED indicator yellow: status of received light beam
3
LED indicator green: supply voltage active
4
Press-turn element: time function adjustment
5
Teach pushbutton: adjustment of light/dark switching
6
Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
Note the sensor's maximum permissible tightening torque of < 1,3 Nm.
Note the preferred orientation of the object relative to the sensor, cf.
page
14.
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
–
Male connector connection: Note pin assignment
–
Cable: wire color
Only supply/switch on the voltage once all electrical connections have been estab‐
lished.
Explanations of the connection diagram (following tables):
Alarm = alarm output
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = test input
U
: 10 ... 30 V DC
B
Table 1: Connections
Wxx26x-
x1
1 = BN
4
2 = WH
3 = BU
4 = BK
1
3
5= GY
WTF26x-xxxxxx31
6
1
2
4
3
x4
xH
4
3
0.14 mm
2
AWG26
1
2
MOUNTING
WTF26x-xxxxxx32
5
1
2
4
3
see figure 3,
x5
xI
5
4
3
0.14 mm
2
AWG26
1
2
4
5