Samsung NA24T4230FS Manual De Instalación página 12

Ocultar thumbs Ver también para NA24T4230FS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation requirements
Single Oven Under counter
H
A
E
G
C
D
F
B
A
Minimum 2" (51 mm)
B
C
Minimum 221/16" / Maximum 22¼" (Minimum 560 mm / Maximum 565 mm)
D
Minimum 1"/ Maximum 1¼" (Minimum 25 mm / Maximum 32 mm)
E
Minimum 23¼"/ Maximum 23½" (Minimum 590 mm / Maximum 596 mm)
F
G
Minimum 22¼" (Minimum 565 mm)
H
Maximum 9½" (Maximum 241 mm) – Junction Box
12 English
01 This cooktop can be installed above any
Samsung single built-in oven. Refer to
installation manual of oven.
02 Gas and Electrical Connections for Gas
Cooktop Must be Located in an Adjacent
Accessible Location near to the cabinet.
03 The distance between the location of the
power cord socket and the appliance cannot
exceed 39
3
/
'' (1000mm), because the length
8
of the power cord is 39
3
/
'' (1000mm).
8
Size
4" (101 mm)
22¼" (565 mm)
Utility locations and dimensions
Front of unit
''
Power cord 39
/
G3/8'' male gas inlet
3
8
(100.0 cm) long
* When you assemble the regulator and brass
connector, the installation angle between the regulator
and the bottom case should be less than 40 ° to avoid
interference with the cabinet.
*When the regulator is installed the cap of regulator so
that it appear to the front to convert the pressure
regulator easily.
3
'' (78.5mm)
1
/ 16
1
''
11
/ 16
(43.5mm)
* The G3/8'' male gas inlet can be turned
when you connect other pipes
Regulator
Brass connector
Less than 40 degrees