• Do not charge the appliance using the 12V connector when the vehicle is occupied. Ensure the area is well ventilated.
• To reduce the risk of electric shock, disconnect the appliance from any power source before attempting maintenance
or cleaning. Turning off controls without disconnecting the appliance will not reduce this risk.
•
Make sure the appliance is disconnected from all charging power sources before beginning the jump start procedure.
• Never attempt to use the ac charger and dc charging connection simultaneously.
additional safety warnings for compressors
• For home and car use only. Inflate car and bike tyres, balls, rafts, swimming pool floats, air mattresses, and more in
and around the home.
• Do not operate the compressor continuously for extended periods of time (approximately 10 minutes, depending on
ambient temperatures), as it may overheat. In this event, the compressor will automatically shut down. Immediately
turn off the compressor power switch. Restart the compressor after a cooling down period of approximately 30
minutes.
• The compressed air from your compressor is not safe for breathing. Never inhale air from your compressor or from a
breathing device connected to the compressor.
• Inflate items only to their manufacturer's recommendations. Exceeding the pressure rating could cause them to
explode resulting in personal injury.
• Do not leave compressor running unattended. It could burst tyres or other items.
• Since the vibration produced by the compressor may cause it to "walk", do not operate on a high shelf or other
surface. Operate at ground or bench level.
• Do not modify or attempt to repair. Never drill into, weld, or make any modifications to the compressor or its
attachments.
• Do not operate compressor when the car engine is running.
• Operate only with the accessories included or those rated for 8.28 bar/120 p.s.i. or higher. The use of any accessory
not recommended for use with this tool could be hazardous.
• Do not play with the tool. High pressure air is dangerous. Don't direct air-flow at yourself or others.
• The compressor can become hot during use. Allow compressor to cool for 30 minutes before storing away.
• Never carry the compressor by the hose.
• This tool is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with
the appliance.
additional safety instructions for batteries and chargers
BATTERIES
• Never attempt to open for any reason.
• Do not expose the battery to water.
• Do not store in locations where the temperature may exceed 40°C.
• Charge only at ambient temperatures between 4°C and 40°C.
• Charge only using the chargers provided with the appliance.
• When disposing of batteries, follow the instructions given in the section "Protecting the environment".
• Under extreme conditions, battery leakage may occur. When you notice liquid on the batteries, carefully wipe the liquid
off using a cloth. Avoid skin contact.
• In case of skin or eye contact, follow the instructions below.
WARning:
The battery fluid is a diluted sulphuric acid and may cause personal injury or damage to property. In case
of skin contact, immediately rinse with water. If redness, pain or irritation occurs seek medical attention. In case of eye
contact, rinse immediately with clean water and seek immediate medical attention.
CHARGERS
Your charger has been designed for a specific voltage. Always check that the mains voltage corresponds to the voltage
on the rating plate.
WARning:
Never attempt to replace the charger unit with a regular mains plug.
Use your charger only to charge the battery in the tool with which it was supplied. Other batteries could burst, causing
personal injury and damage.
• Never attempt to charge non-rechargeable batteries.
• Have defective cords replaced immediately.
• Do not expose the charger to water.
• Do not open the charger.
• Do not probe the charger.
The battery must be placed in a well ventilated area when charging.
EnglisH
J5C09EU_Manual_040512.indd 4-5
4
This unit is double insulated; therefore no earth wire is required.
Fail-safe isolating transformer. The mains supply is electrically separated from the transformer output.
The jump starter is intended for household use only.
electrical safety
Always check that the power supply corresponds to the voltage on the rating plate.
• If the supply cord is damaged, it must be replaced by the manufacturer in order to avoid a hazard.
features
1. USB power button
2. USB charging port (under protective cover)
3. 12 volt dc accessory socket (under protective cover)
4. USB power indicator
5. Battery status LED indicators
6. Reverse polarity indicator
7. Jump-starter power switch
8. Pivoting LED area light power switch
9. Pivoting LED area light
10. Battery power level button
11. Ac to dc charging socket
12. Air pressure gauge
13. Positive (+) red clamp
14. Air hose and nozzle
15. Compressor power switch
16. Negative (–) black clamp
17. 12 volt dc charging adapter
18. Adapter nozzles
19. Mains charging adapter (EU model)
20. Mains charging adapter (GB model)
use
charging the unit
This unit is shipped in a partially charged state.
• Charge the unit before first use using the mains charging adapter for 36 hours.
Lead-acid batteries require routine maintenance to ensure a full charge and a long battery life. All batteries lose energy
from self-discharge over time and more rapidly at higher temperatures. When the unit is not in use, manufacturer
recommend that the battery is charged at least every 30 days.
• Check the battery charge level by pressing the battery status pushbutton. The LED charge status display will indicate
the level of battery charge. When only one red LED lights, charge the unit.
• Make sure all other unit functions are turned off during recharging, as this can slow the recharging process.
note:
Charging the battery after each use will prolong the battery life; frequent heavy discharges between charges and/or overcharging will
reduce battery life.
important!
When the battery is overly discharged and if the green LED is lit when the charger is plugged in, this
indicates the battery is at a high impedance stage. In this event, recharge the unit and leave the unit charging for a
period of 36 hours before use.
CHARGING THE UNIT USING THE MAINS CHARGING ADAPTER
• Insert the jack of the appropriate mains charging adapter (either the EU model or the GB model) into the 12V AC/DC
charging socket on the back of the unit.
• Insert the appropriate mains charging adapter plug into a mains power socket.
• Charge until two red and one green (full) battery status LEDs light or flash.
5
EnglisHn
4/5/2012 7:56:26 PM