Descargar Imprimir esta página

BFT LEO B CBB DL2 3 230 L02 Manual De Instrucciones página 39

Ocultar thumbs Ver también para LEO B CBB DL2 3 230 L02:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 60
Logic
De nition
Con guration of
command input
IC 1
IC 1.
61
Con guration of
command input
IC 2
IC 2.
62
Con guration of
command input
IC 3
IC 3.
64
Con guration of
command input
IC 4
IC 4.
65
Con guration
of the 1st radio
1ch
channel command
Con guration
of the 2nd radio
2ch
channel command
Con guration
of the 3rd radio
3 ch
channel command
Con guration
of the 4th radio
4 ch
channel command
Con guration of
AUX 0 output.
AUX 0
20-21
AUX 3
(Setup for
LEO B CBB DL2
Con guration of
3 120 F02 PHOT
AUX 3 output.
26-37
USA16)
LEO B CBB DL2 3 120 F02
(only for sw versions
7.08)
Fixed code
FIXED CODE
Setting the
Protection
protection level
level
Serial mode
(Identi es how
SERIAL MODE
board is con gured
in a BFT network
connection).
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Input con gured as Start E.
0
1
Input con gured as Start I.
2
Input con gured as Open.
4
3
Input con gured as Close.
4
Input con gured as Ped.
2
5
Input con gured as Timer.
3
6
Input con gured as Timer Pedestrian.
0
Radio control con gured as START E.
0
1
Radio control con gured as Start I.
2
Radio control con gured as Open.
3
Radio control con gured as Close
4
Radio control con gured as Ped
9
5
Radio control con gured as STOP
6
Radio control con gured as AUX0 **
7
Not used
2
8
Not used
9
Radio control con gured as AUX3 **
10
Radio control con gured as EXPO1 **
5
11
Radio control con gured as EXPO2 **
0
Output con gured as monostable Radio Channel.
1
Output con gured as SCA (gate open light).
2
Output con gured as Courtesy Light command.
3
Output con gured as Zone Light command.
6
4
Output con gured as Stair Light
5
Output con gured as Alarm
6
Output con gured as Flashing light
7
Output con gured as Latch
8
Output con gured as Magnetic lock
9
Output con gured as Maintenance
10
Output con gured as Flashing Light and Maintenance.
11
Not used
0
12
Output con gured as Antitampering
13
Output con gured as Gate Status
14
Output con gured as Bistable Radio Channel
15
Output con gured as timed Radio Channel
Receiver is con gured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
Receiver is con gured for operation in xed-code mode.
1
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memo-
rized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by
0
repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the receiver's
memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
0
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interference,
if any.
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
0
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network with no
2
smart module ( g.F)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network with no
3
smart module ( g.F)
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120
Optional extras
F02-LEO B CBB DL2 3 120 F02 PHOT USA16
39
-

Publicidad

loading

Este manual también es adecuado para:

Leo b cbb dl2 3 120 f02Leo b cbb dl2 3 120 f02 phot usa16