14. Clear all the Logged data
14.1 Hold the trigger while in LOG mode and press DOWN arrow key same time until you reach LOG
location "000".
14.2 Hold the trigger and then press the Backlight/Laser key (Pos 5) once and release.
(you will hear a tone and the LOG location will automatically change to "001". All stored data have
now been cleared.
Note: You can only reach "0" by using DOWN key.
15. Type K measurement
Insert Type K plug into type K sockets, (Pos. 3) " TK " will appears in the left corner of the screen and the
temperature value will be shown.
16. Data transfer
16.1 When in measuring mode, press and hold the Backlight/Laser key until the USB sign appears in the
right lower corner of the LCD.
16.2 Connect the device to computer by USB cable (Pos. 4) and transmit data to the preinstalled software.
16.3 To turn off USB function, press and hold the Backlight/Laser key until the USB sign disappears.
17. Find heat and cold point
Aim the thermometer at target area and start to measure, then move up and down slowly to sweep the whole
area until the heat point and/or cold point are found.
7
English
GB