ProMed 5040 SX Instrucciones De Empleo página 26

Aparato de manicura-pedicura
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
o
PeratinG tHe unit
J. Rotating direction, clockwise / counterclockwise
• The default direction is clockwise and is displayed on user-
DE
interface through a blue LED on the right side of the button (C)
.
EN
• By pressing the button (C)
then illuminates the LED on the left side of the button (C)
It is recommended to perform the change in direction when the
FR
motor is stationary, or reduce the speed up to maximum approx.
10.000 rpm. Avoid switching off at higher speed because then
IT
there is too much load on the engine.
ES
K. Spray setting
• The Promed 5040SX is equipped with powerful micro pump
which controls the finest spray.
PT
• The control of spray volume depends on the buttons (H)
(I)
and can be adjusted in 10 levels (1 - 10 corresponding
PL
10 % - 100 %).
• If the buttons (H)
quickly the strength of the spray quantity.
• For e.g. if you need 80 % spray quantity, then press the button
(H)
, till it is shown on the display (F)
• The display immediately changes back to the speed indicator
provided that no further spray quantity is controlled.
the direction can be changed. It
or (I)
is pressed, the display shows
.
L. SPRAY- Standby-Function
• In order to interrupt the supply of spray, press the button (G)
, this „pause-Standby-function" represents the spray output. The
compressed air pump continues to operate so that the nozzle
blows out only the air. The spray supply is interrupted. The
.
handpiece is still rotating. During the standby state, the blue LED
blinks on the button (G)
remains unchanged during the break.
• By repressing the button (G)
Please note:
If you work with the spray function switched off, below the control
units, very fine spray mist will always escape from the nozzle.
or
M. Overload protection for motor handpiece
• In case of any blockage or strain of the handpiece, the engine
and micropump turns off for approx. 5 seconds
• The handpiece overloading is shown on the display (F) by an
error message
. After a few seconds, the display disappears
and the unit is in standby mode.
• If the handpiece shows a defect, the error message is displayed
on the display (F)
• In this case the complete device (control with handpiece) should
be sent to an authorized dealer for maintenance and repair.
. The adjustment of the spray intensity
the spray supply is reactivated.
.

Publicidad

Tabla de contenido
loading

Tabla de contenido