E N G L I S H
Symptom
Cause
Tool does not count
1. Rivet break load is too small, it is under
correctly (does not
count or counts even if
2. Riveting cycle is too fast.
it does not set rivet).
Pulled trigger before judgement.
3. Setting data are broken
Rivets / Charge is low.
1. Smart function is turned on.
2. Battery is not fully charged
3. Battery is defective
2,000N
Remedy
Counter function cannot be used in
very low break load rivet.
Pull trigger for next riveting after
judgement.
Restore to factory settings
Rivets / Charge decreases, if smart
function is turned on. Turn on/off
smart function as needed.
Check battery charge level and
charge battery
Replace battery
38
Page
8
-
31
14
31 or
Refer to tool
manual
-