Battery Charging Status LEDs
Condition
No battery pack installed
Charging in progress
Charging complete
Battery pack out of temperature range
Fault condition
A fault condition occurs if the battery temperature is outside the
normal operating temperature for the charger. The fault clears
and charging resumes when the battery temperature returns to
the normal operating range. If a fault condition does not clear
under normal operating temperature range, this may indicate a
defective battery.
Power Usage
Each charger power supply (model 073573) uses approximately 1
amp of current. You can have 20 battery pack chargers plugged
into one 20-amp circuit assuming no other loads are drawing off
that circuit breaker.
Electrical Rating
• Quad Charger (Model AC14) 12 VDC @ 4.15A
• Power Supply ( Model 073573) AC 100-240 VAC, 47-63 Hz
@ 1A