100
0x880-039
Technical characteristics
POWER SUPPLY
INDICATORS
DIMENSIONS
230VAC
1 LED
50Hz
55x55x72mm
(+-10%)
*
*
For more information on the EU
®
Declaration of Conformity and Z-Wave
frequencies, consult the product sheet on
our website simonelectric.com
Select the appropriate location with a weak Z-Wave
1
signal to install the socket and insert the device into
the socket outlet in order to capture weak or slow
signals and efficiently repeat them over the rest of
your Z-Wave network.
Download the Simon iO application. After creating
2
the installation, go to "Devices" and click on add
device, which can be found at the top right of the
application.
A
B
Download the Simon iO
Go to "Devices" and click on
application.
add device.
Press for three seconds on the inclusion button. And
3
the LED will blink intermittently until the device is
included.
Inclusion button
To ensure good transmission quality, keep away from sources
of interference such as metal surfaces, microwave ovens, hi-fi
equipment, televisions, ballasts or transformers.
ENGLISH
DESCRIPTION
The iO Z-Wave Repeater socket can extend the range of communication between iO products
and assist other Z-Wave devices to reach each other on your Z-Wave network without losing a
socket outlet.
KEYPAD USE & FEEDBACKS FOR SWITCH
EVENT
BUTTON
DEVICE
LEDs
ACTION
STATUS
FEEDBACK
Not pressed
Not included on a
Blue LED blinks slowly
Z-Wave Network
Included on a
Blue LED (ON)
Z-Wave Network
LED off (OFF)
Blue LED (Overload
protección)
Pressing the button
Short press
Button blocked
Blue LED blinks 3 times
(t<2s)
and then recovers accor-
ding to the relay state
Button not blocked
Turns on Blue LED
or turns off LED
Add/Removing device
Long press
LED blinks intermittently
from Z-wave Network
(2s<t<30s)
every 300ms
Reset default
Long press
LED turns on for 2,5
(t>30s)
seconds then turn OFF
Z-WAVE COMPLIANCE
This is a Z-Wave Plus® Product using the latest S2 Security Encryption. This product can be ope-
rated on any Z-Wave network with other Z-Wave certified devices from other manufacturers.
All non-battery operated nodes within the network will act as repeaters regardless of vendor to
increase the reliability of the network.
Z-WAVE SPECIFICATIONS
Z-WAVE DEVICE SPECIFICATION
SUPPORTED COMMAND CLASSES
COMMAND CLASS Z-WAVE PLUS INFO V2
Device Type
ON/OFF/Power Switch
COMMAND CLASS SWITCH BINARY V1
Generic Device Type
COMMAND CLASS METER V3
COMMAND CLASS TRANSPORT SERVICE V2
Specific Device Type
SPECIFIC_TYPE_POWER_
COMMAND CLASS SUPERVISION V1
COMMAND CLASS SCENE ACTUATOR CONF V1
SWITCH_BINARY
COMMAND CLASS SCENE ACTIVATION V1
Role Type
Always on Slave
COMMAND CLASS CONFIGURATION V1
COMMAND CLASS ASSOCIATION GRP INFO V1
COMMAND CLASS ASSOCIATION V2
COMMAND CLASS MANUFACTURER SPECIFIC V2
COMMAND CLASS VERSION V2
COMMAND CLASS FIRMWARE UPDATE MD V3
COMMAND CLASS POWERLEVEL V1
COMMAND CLASS SECURITY V1
COMMAND CLASS SECURITY 2 V1
COMMAND CLASS DEVICE RESET LOCALLY V1
ASSOCIATION GROUPS
Number of Groups
Group 1 General: Lifeline
Max. devices in Group
5
Automatic reports
1. Basic Report 2 seconds after last relay change according report configuration value
2. Meter Report (Watts) report after power measurement changes more than 10% from last
reported value and if this value is stable during 2 seconds.
Number of Groups
Group 2: Ctrl
Max. devices in Group
20
Actions
1. Basic Report
CONFIGURATION
NAME
SIZE
VALUE
105
Overload
1
0x00 --> Overload protection is disabled
Protection
0xFF --> Overload protection is enabled
19
Post reset status
1
0x00 --> Does not recover status
0x01 --> Recovers to on
0xFF --> (Default) recovers last status
106
Notification values
1
0x01/0x02 Basic Report reports have to be sent 2s after load changes
12
Led in Repose
1
0x00 --> In repose mode, LED is OFF. When the user presses the pushbutton
and the load changes to ON, the LED turns ON only for 5s
0xFF --> If Load is OFF, the LED is off. If Load is ON, the LED is white.
13
Lock pushbutton
1
0x00 --> Push button enabled
0xFF --> Push button disabled
20
Identify
1
0xFF --> Each time that configuration setting parameter 20 is received, the
device's LED will flash for 100ms periods during 5s with 100ms period during 5s
15
Restore device
2
0x4312 Configurations are restored to default values
0x9867 Device performs a factory reset action. Configurations to
default, device reset notification sent, and associations removed. 100ms
periods during 5s
DEVICE
ACTION
Change load ON-OFF
status
The device sends a Node Info
to include or exclude from the
Z-Wave Network
Configurations are set to
default values, it sends a
"Device Reset Locally to
Z-Wave controller" and
excludes from current
Z-Wave network
SIMON, S.A.U. Diputación, 390-392 / 08013 Barcelona
sat@simon.es Tel: (+34) 902109700
www.simonelectric.com

Publicidad

loading