Descargar Imprimir esta página

koban KSC-02 Manual De Instrucciones página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Mounting and operation
Attention: The installation of electrical devices must be done by an authorized
installer..
1. Designed to easily connect to a switchboard of electrical switches; just set the timer on the
1. Designed to easily connect to a switchboard of electrical switches; just set the timer on the
DIN rail and press it until it clicks into place "Click" To remove it, push the latch on the bottom
DIN rail and press it until it clicks into place "Click" To remove it, push the latch on the bottom
of the timer and release.
of the timer and release.
2. Once the connections have been made, it is necessary to select through the controls
2. Once the connections have been made, it is necessary to select through the controls
control the type of operation desired and the activation time of the light load.
control the type of operation desired and the activation time of the light load.
Possible operating modes:
Possible operating modes:
In
Out
T
T
T
T
In
Out
T
T
T
T
In
Out
T
T
In
Out
T
T
In
Out
In
Out
SC - Staircase function
On initial impulse the output contact closes and timing starts for the
pre-set duration; subsequent impulses during the timing period wil
l extend the timing period by the full pre-set value. On expiry of the
T
T
T
T
time delay,the output contact opens.
SC - Staircase wth early warning function
On initial impulse the output contact closes and the timing starts for
the pre-set duration. After the timing period, the output contact
blinks off once; 10secs later the contact blinks off twice, and after a
T
T
further 10secs the contact opens. During the pre-set and 20 second
warning time, it is possible, by a further impulse, to extend the time
by the full pre-set value.
TR - Timing step function
On initial impulse the output contact closes and the timing starts for
the pre-set duration.On expiry of the time delay, the output contact
T
T
opens. During thetimming period it is possible to immediately open
the contact with a further impulse.
TW - Timing step with early warnin function
On initial impulse the output contact closes and timing starts for
the pre-seduration; After the timing period, the output contact
T
T
blinks off once; 10 secs laterthe contact blinks off twice, and after
a further 10 secs the contact opens. During the pre-set and 20
second warning time, it is possible to immediatelyopen the output
contact by a further impulse.
SR - Step relay function
On initial impulse the output contact closes and timing starts for
the pre-se open to closed and vice versa.
- Light on function
With this function set - the output contact stays permanently closed
KSC-02
Staircase time switch
.
.
-8-

Publicidad

loading

Este manual también es adecuado para:

0767627