the adjustment bar. Besides this function, the display
screen also shows Pause Time. If we select this, by
means of the adjustment bar, we can regulate the
pause time between one welding point or section and
another. The pause time varies between 0 (OFF) and 5
seconds.
To access the Spot Time and Pause Time functions,
press the knob B for less than 2 seconds. Adjustment
is always made by means of the knob B. To confi rm,
simply press it for less than 2 seconds. Once the
choice has been confi rmed, return is always made to
the display page (PROCESS PARAMS).
• Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting
is zero. If the fi gure is negative, the impedance drops
and the arc becomes harder, while if it increases, the
arc is softer.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The fi gure can be
changed and confi rmed by pressing the knob B for less
than 2 seconds.
• AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose
is to adjust the length of the wire coming out of the gas
nozzle after welding. A positive fi gure corresponds to
greater wire burning.
Default is Auto.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The fi gure can be
changed and confi rmed by pressing the knob B for less
than 2 seconds.
12
All manuals and user guides at all-guides.com
• Soft Start AUTO
• Options LOCK
• Factory OFF
Adjustment can vary from 0 to 100%. This is the wire
speed expressed in percentage of the speed set
for welding, before the wire touches the piece to be
welded.
This adjustment is important to always obtain good
starts.
Default is Auto.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The fi gure can be
changed and confi rmed by pressing the knob B for less
than 2 seconds.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A will show a serial number SN and 8 zeros.
The purpose of this function is to unlock the blocked
synergic curves.
To unlock the curves, instead of the zeros, an
alphanumeric code must be entered. This must be
requested from your dealer, after indicating the serial
number SN.
Once the code has been obtained, simply enter it in
place of the zeros, Each letter or fi gure entered must be
confi rmed by briefl y pressing the knob B. After entering
the code, by pressing the knob B for more than 2
seconds, all the curves are unlocked and the display
screen A shows UNLOCK alongside the Options
function.
The purpose is to return the welding machine to the
original default settings.
To access the function, simply highlight it using the
knob B. By pressing this for less than 2 seconds, the
display screen A shows the words OFF and ALL. By
highlighting the word ALL and briefl y pressing the knob
B reset is made and the display screen A shows Factory
Done!! This indicates the reset has been successful. To
return to the previous display page, simply press the
knob B for more than 2 seconds.