Service Spark Plug; Battery Replacement (If Applicable) - Generac XT Serie El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

C
B
A
Figure 4-3. Air Filter Assembly

Service Spark Plug

To service spark plug:
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Inspect electrode gap with wire feeler
gauge and reset spark plug gap to 0.028-
0.031 in (0.70-0.80 mm). See
Figure 4-4. Spark Plug
NOTE: Replace spark plug if electrodes are
pitted, burned or porcelain is cracked. Use
ONLY recommended replacement plug. See
Specifications.
4. Install spark plug finger tight, and tighten
an additional 3/8 to 1/2 turn using spark
plug wrench.
Battery Replacement
(if applicable)
NOTE: The battery shipped with the generator
has been fully charged. A battery may lose
some charge when not in use for prolonged
periods of time. The battery may have to be
charged before the first use. Running the gen-
erator will NOT charge battery.
Accidental Start-up. Disconnect the negative battery
cable, then the positive battery cable when working
on unit. Failure to do so could result in death
or serious injury.
1. See
Figure
4-5. Disconnect and remove
the battery connecting hardware (8mm)
and BLACK wire (B) from the battery's
NEGATIVE (-) terminal.
16
004547
Figure
WARNING
(000130)
2. Remove the red rubber boot (A) and dis-
connect the battery connecting hardware
(8mm) and RED wire (A) from the battery's
POSITIVE (+) terminal.
3. Remove screws and bracket from battery
tray to remove battery.
4. Install new battery and replace battery
bracket and screws.
5. Connect RED wire to the POSITIVE (+)
battery terminal (A). Slide rubber boot over
connection hardware.
6. Connect BLACK wire to the NEGATIVE (-)
battery terminal (B).
B
4-4.
000211
Environmental Hazard. Always recycle batteries at an
official recycling center in accordance with all local
laws and regulations. Failure to do so could result in
environmental damage, death or serious injury.
Battery Charger Fuse Replacement
The charging port is protected by a 1.50 Amp
replaceable in-line fuse. If the charger is not
charging the battery, check the fuse.
NOTE: To order a new fuse, contact the near-
est IASD at 1-888-GENERAC (1-888-436-
3722).
The battery charger fuse is located behind the
control panel. See
1. Remove rubber coated clamp.
2. Pull apart the two halves of the fuse holder
to remove fuse.
3. Install new fuse and push halves of fuse
holder together.
4. Route all wires away from engine compo-
nents and secure with rubber coated
clamp.
Figure 4-5. Battery Connection
WARNING
Risk of burn. Do not open or mutilate batteries.
Batteries contain electrolyte solution which can
cause burns and blindness. If electrolyte contacts
skin or eyes, flush with water and seek immediate
medical attention.
WARNING
Figure
4-6.
Owner's Manual for Portable Generator
A
004549
(000163a)
(000228)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

G0064331

Tabla de contenido