Electrical Shock Hazard; Choosing The Installation Location; Electrical Connections - TATRA TW.F50+DR Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
Pressure measured
0 - 2 bar
2 - 4 bar
over 4 bar
A sewer drain must be provided on the floor or on the wall where the dishwasher will
be located. If the dishwasher has a built-in drainage pump, the sewage drain shall be
installed at the level lower than 600 mm from the floor. If you are using a model without
a drain pump, the drain must be at floor level.
A dishwasher pot is adjusted to operate at a temperature of 55
o
85
C. It is strictly forbidden to change the values on thermostats to ensure the
dishwasher performance stay the same.
ATTENTION!
Failure to comply with the above operating conditions will adversely affect the
performance of the dishwasher.

ELECTRICAL SHOCK HAZARD!

The power connection line to the dishwasher must be properly grounded. The
manufacturer shall not be liable for damage resulting from the operation of the
dishwasher without grounding or with insufficient grounding.
4.2.

Choosing the installation location

The environment is important for the smooth operation of your dishwasher. Please,
follow the steps below before installing the dishwasher.
Place the dishwasher on a flat, solid surface. Installing on uneven surface may result in
an incorrect water level and may affect the operation of the door.
The surface on which the dishwasher is installed must withstand its load.
Do not place the dishwasher in a place where the temperature drops below 0
Place the dishwasher in a place as close to water and sewage as possible.
To avoid any drops and overturns, do not place the dishwasher on an uneven surface.
4.3.

Electrical connections

To perform the electrical connection of the dishwasher, unpack all the parts and place
the dishwasher in the desired location taking into account the recommendations on choosing the
installation location given in the operation manual.
ATTENTION!
- Before making the electrical connection, first compare the technical conditions
of the local power supply with the parameters given in the dishwasher manual.
The manufacturer and the seller disclaim all liability if the power connection is
not protected with a fast response circuit breaker.
Only authorized personnel is allowed to mount and connect the dishwasher.
The device must be connected to an electrical network conforming to DIN VDE 0100.
The device must be grounded.
The main circuit breaker to which the device will be connected, must be provided with
a leak relay of 30 mA.
Voltage surges shall not exceed ± 10%.
It is necessary to provide an automatic switch corresponding to the highest voltage
indicated on the device in the electrical network to which the dishwasher is connected.
Necessary procedures
A hydrophore should be provided.
No additional procedures are required.
A pressure regulator should be provided.
EN
C, and the boiler – at
o
o
C.
33