To oversee connection of the building's electrical supply, a
cable with a suitable cross-section, (220-240 V ~:min. 4 mm2;
380-415 V 2N ~: min. 2.5 mm2) must be used.
The building's electrical supply must be equipped
with a differential switch with operating current
which does not exceed 30 mA.
Frame shower enclosures have a terminal identified by the
symbol
, placed on the back of the frame for equipotential
connection of the surrounding metal masses (standard EN
60335.2.105).
The appliance is equipped with an LED lighting system in
compliance with Norm EN 62471:2009, lamp classification
group: exempt.
Do not look directly at the light using optical devices (bin-
oculars, cameras, magnifying glasses).
ATTENTION! Before carrying out any maintenance
operations, disconnect the appliance from the power
supply line.
JACUZZI EUROPE S.p.A. denies all responsibility:
- If installation is carried out by unqualified personnel and/or per-
sonnel unauthorised to carry out the installation itself.
- If current norms and legal provisions regarding the electric sys-
tems of buildings in the country in which installation is carried out
are not complied with.
- If the instructions for installation and maintenance contained in
this manual are not followed.
- If unsuitable and/or uncertified materials are used for installa-
tion.
- If shower enclosures are placed in areas which do not comply with
the above-quoted standards.
- If incorrect operations are performed that reduce the level of pro-
tection of the electrical equipment against water jets, modify the
protection against electrocution due to direct or indirect contact,
or produce abnormal conditions of insulation, current leakage or
overheating.
- If any components or parts of the appliance are altered in rela-
tion to the original state when supplied, releasing the Manufacturer
from any liability.
- If the appliance is repaired by unauthorised personnel or if spare
parts are used other than the original ones supplied by Jacuzzi Eu-
rope S.p.A.