After Operation; Disconnect Compressed Air Supply; Remove Compressed Air Hose (Only For Air-Powered Stapler Units); Emptying The Magazine - Prebena KTVH-B19D Manual De Instrucciones Original

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

After operation

Carry out the steps described below after operation or during
extended interruption of operation.

Disconnect compressed air supply

Remove compressed air hose (only for air-powered stapler
units)
 Pull the quick release of the compressed air hose from the push-
in nipples.
Quick release is now unlocked.
 Disconnect the compressed air hose from the connection from the
stapler unit
The compressed air contained in the stapler unit escapes audibly.

Emptying the magazine

Remove the fasteners not used in the magazine, if you no longer use
the stapler. To do this, proceed as follows:
 Open the magazine (2) (see page 21).
 Slide the fasteners (13) remaining in the magazine to the back of
the inlet.
 Remove the fasteners (13) remaining in the magazine (2).
WARNING
Accidentally triggering when emptying the
magazine can cause serious injury or death.
 Disconnect the stapler unit from the
compressed air supply (see page 33).
After operation
33

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ktvh-b19hKtvh-b22dKtvh-r19dKtvh-r19h

Tabla de contenido