Drawing Title: LS-B-159-4000-05
ESPECIFICACIONES DE INSTALACIÓN (continuación)
INSTALACIÓN DE LA PLACA DE ABRAZADERA (CABEZAL CON CABEZAL)
**CLAMP PLATE INSTALLATION FOR PINS ≤ Ø0.25 [7.0]; PINS > Ø0.25 [7.0] USE HEAD-TO-HEAD INSTALLATION.**
J
M
Refer to Product Manual for Cover Plate Alternatives
NOTES:
1.
CLAMP PLATE APPLICATIONS REQUIRE GUIDED EJECTION
2.
EJECTOR AND TRANSFER PIN CONCENTRICITY MUST BE WITHIN 0.030" [0.76] OR
10% OF EJECTOR PIN DIA, WHICHEVER IS SMALLER.
3.
ENCLOSED EJECTOR BOX SUGGESTED.
4.
DO NOT SCALE PRINT
5.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
6.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
7.
TOLERANCES UNLESS SPECIFIED:
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
ANGLES = 3 30
Manual del Producto | Galga Extensométrica Monocanal Lynx ™ 4000 Libra Sensor de Botón LS‑B‑159‑4000
LS-B-159-4000 Single-Channel Sensor Installation—Head-to-Head Installation
B-Plate or Cavity Insert
Ejector Pin Installed with
Normal Slip-Fit Tolerances
H7/g6
Ejector Retainer Plate
Ejector Plate
0.5 MIN [12 MIN]
H7/g6
Fit Must be 1/3 of Pin Length MIN
Ejector Pin Shoulder
and Transfer Pin
Clamp Plate
Cover Plate 32HRC
0.25 MIN [6.0 MIN] Plate Thickness
Standard Fit
0.02 MIN
0.5 MIN
Per Side
45°
REFER TO
TABLE J
H7/g6 for
0.02 MIN
0.5 MIN
0.5 MIN
[12 MIN]
Per Side
DETAIL J
SCALE 3 : 1
Equal
L
0.001 [0.03] l
0.001 [0.03]
+
0.005
0.635
-
0.000
[16.13 0.1]
DETAIL M
SCALE 1.5 : 1
45°
REFER TO
TABLE J
Part Thickness < 0.05 [1.5], 1/5 of Thickness
Part Thickness > 0.05 [1.5], 0.01 [0.3]
TABLE J
Ejector Pin Ø
Chamfer Length
0.04–0.08 [1.0–2.0]
0.10–0.20 [2.5–5.0]
0.24–0.40 [6.0–10.0]
0.01 MIN
0.3 MIN
Counterbor in Ejector Plate
Transfer Pin Flush with Ejector Plate
Transfer Pin
+
0.04 IF < 0.12 [1.0 IF < 3.0]
0.06 IF > 0.12 [1.5 IF > 3.0]
30° Chamfer
Depth Equal to Pin Ø
0.01 MIN
0.3 MIN
+
0.002
0.500
-
0.001
[12.7 0.04]
Description: LS-B-159-4000
Sensor Installation
Drawn: K.J.Brettschneider
Design:
Check: M.Groleau
Date: 11.18.2021
0.01 [0.3]
0.02 [0.4]
0.025 [0.6]
RJG, Inc.
15