Kit Contents: K1
A1
Fig. 1
New
Ref.
Description
K1
A / A1
Gas Train Assembly / Screw
NI
B
Gas Train Support Bracket
NI
C
Gas Train Base
NI
D
Gas Supply Line Fitting
NI
E
Timing Marks
NI
F
Gas Supply Line
NI
Not Included: Reference Only
Tools Needed:
■ 6 inch Needle Nose Pliers
■ 7/8" Wrench - for gas supply line fi tting
■ 3/4" Wrench - for gas train assembly
■ 1/4 inch Nut Driver
■ Refrigerator Service Manual
This procedure is to be performed by
WARNING
!
authorized service personnel only. Im-
ATTENTION
proper installation, adjustment, alteration,
service or maintenance can cause injury
or property damage.
Remove Part
Be sure the appliance has been isolated
WARNING
!
from the gas and electrical supply before
ATTENTION
starting! Refer to Service Manual for
details.
Never attempt to operate the gas train
WARNING
!
when it is NOT installed in the cooling
ATTENTION
unit because of the risk of electrical
shock.
1. Disconnect two (2) white wires from
2. Using two (2) wrenches, remove
3. Remove
(2x) and
; set aside.
A1
B
4. Remove
from
.
A
C
P.O. Box 1285
Ann Arbor, MI 48106
www.norcold.com
N7, N8, & N10 Series Gas Train
K1
A
B
C
A
.
F
from
A
.
Questions 1-800-543-1219
F
Fig. 2
D
E
F
Fig. 4
Replace Part
1. Using new part, reverse Steps 4 through 1 to replace and
reinstall.
2. Hand thread
onto
until it is fi nger-tight.
D
K1
3. Apply
to
and
. Refer to Fig. 2.
E
D
K1
4. Use the double wrench technique to avoid twisting the frame of
. Refer to Fig. 3. If
K1
K1
be replaced.
Always use two wrenches to tighten
WARNING
AVERTISSEMENT
ADVERTENCIA
!
!
!
!
DANGER
or loosen propane gas connections.
ATTENTION
ATTENTION
ATTENTION
ATTENTION
Damaged connections, piping, and
components create the potential for gas
leaks.
5. Using two (2) wrenches, tighten to 1/8 of a turn more. Notice
the different position of the timing marks. Refer to Fig. 4.
Test Propane Gas Connection for Leaks
Do not wet or spray leak test solution on
WARNING
!
or near electrical connections or electri-
ATTENTION
cal components. All leak test solutions
conduct electricity and may create an
electrical shock hazard, shorts, and / or
damage circuits.
Do not use any leak test solution that
WARNING
!
contains ammonia or chlorine. Ammonia
ATTENTION
and chlorine corrode brass and copper
components.
639572
Service Kit
639592
F
A
A
Fig. 3
becomes bent or twisted, it MUST
Part No. 639571C (01.14.2020)