Descargar Imprimir esta página

General Safety Instructions - SAMES KREMLIN STD 9 Manual De Instrucciones

Ocultar thumbs Ver también para STD 9:

Publicidad

Dear Customer, we would like to take this opportunity to thank you for buying a new electrostatic power
supply unit. We are confident that you have made the right choice.
We have taken every care, from original design to final manufacture, to ensure that this product gives you
complete satisfaction. To obtain the best performance and reliability from this equipment, we would strongly
advise you to read this instruction manual attentively before attempting to use the equipment.

1. GENERAL SAFETY INSTRUCTIONS

BEFORE CONNECTING THE STD 9 POWER SUPPLY ON THE MAIN POWER
SOURCE, BE SURE IT IS COMPATIBLE WITH THE LOCAL VOLTAGE
SOURCE (110 VAC/60 Hz or 220 VAC/50 Hz) – IF REQUIRED SWITCH
COMMUTATOR (E).
1 - The non-compliance with the safety requirements and precautions stated in this
manual could result in unsafe conditions.
2 -
The personnel involved in operating and servicing the electrostatic coating equipment must be fully
aware of all safety requirements stated in this manual.
3 -
The workshop supervisor must be certain that the personnel has perfectly understood the safety
instructions and complies with them. These instructions cover the precautions required for solvent-
based paint spraying and the specific precautions in connection with the use of equipment requiring
high voltage.
The personnel must also be familiar with the local safety standards which can be in force in certain
countries.
INSTALLATION
4 -
Spraying, cleaning and servicing must be made in a ventilated area so that solvent vapours are
properly drained.
5 -
STD 9 power supply unit must be installed in a non-hazardous area. Moreover, it must be located
4 meters (13 ft) at least away from any flammable vapour emissions.
6 -
All metallic parts located within 3 meters (10 ft) around the gun (such as pumps, drums, conveyor,
etc ...) must be correctly grounded.
7 -
Storage of paint and solvent drums near or inside the spraying area is prohibited. Keep all fluid
containers properly closed in a non-hazardous area.
Use cleaning solvents with the highest flash point - If possible, higher than the ambiant
temperature.
8 -
Remove the useless parts from the spraying area and keep this area clean. Part holders and
conveyor hooks must be removed and frequently cleaned.
9 -
The floor must be electrically conductive and grounded. Maximum resistivity of the floor : 1 M as
per EN 50 053-7-2.
10 - The warning sign must be affixed in the spraying area and located where it can be easily seen and
read by all operators.
SPRAYING
11 - Never point the spray gun to anyone or any part of the body.
12 - Never throw or drop the electrostatic manual gun. Any misuse of the spray equipment or
accessories can damage them and result in serious body injury, fire or explosion.
KREMLIN REXSON
Page 2
Manual : 573.162.112

Publicidad

loading

Este manual también es adecuado para:

Std 9 aStd 9 b