INSTALLATION
(Section reserved for qualified installers of the range hood)
The recommended distance between the cooker and the lower part of the
range hood for the installation is about 110 cm. In borderline cases, with
a slight efficiency loss, the distance can be increased to about 150 cm. The
minimum distance cannot be less than 65 cm, as envisioned by the Standard.
cooking on the cooking device and the lowest part of the kitchen range hood.
Should the instructions of the gas cooker specify a greater distance, take this
into consideration.
In the outside exhaust version, the diameter of the fume discharge duct must
be no smaller than the range hood connection.
In the horizontal sections, the duct must slope slightly (around 10%) upwards,
so at to better convey the air outside of the room.
Reduce curves to the bare minimum, and check that the length of the ducts is
also the bare minimum.
Comply with the current regulations on air discharge into the atmosphere.
If other appliances that use gas or other fuels are being used at the same
time (boiler, stove, fireplaces, etc.), make sure the room where the fumes are
extracted is well ventilated, in compliance with the current regulations.
Assembly instructions: see section "O" of the booklet.
D

ELECTRICAL CONNECTIONS

(Section reserved for qualified installers)
WARNING!
Before doing any work inside the range hood, disconnect the appliance from
the mains power supply.
Check that the wires inside the range hood are not disconnected or cut; if this
is the case, contact your nearest service centre. The electrical connections
must be performed by qualified personnel.
The connections must be performed in compliance with the legal standards in
force. Check that the relief valve and the electrical system are able to support
the load of the appliance (see the technical specifications in point B).
Some types of appliance are supplied with a cable without plug; in this case,
"standardised" plugs must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
- the blue wire must be used for the neutral,
- the brown wire must be used for the phase; the cable must not come into
contact with hot parts (over 70°C).
- fit a plug that is suitable for the load to the power cable, and connect it to a
suitable power outlet.
For appliances that come supplied with cable and plug please ensure they are
plugged into a circuit suitable for this appliance.
Please refer to a qualifed person. (See technical specifications in point B).
The manufacturer declines all liability if the safety standards are not ob-