ATTENTION, the false ceiling must be suitably reinforced to safely support the range
hood.
Remove the AP openable panel and the metallic filters (see fig. 1).
Find installation type for outside exhaust version:
With motor unit (UM) (MU) fixed on the range hood:
1) Remove the FC flange assembled on the range hood and the FM flange as-
sembled on the UM (fig. 1). Define the direction of air outlet by rotating the
FL flange of the motor unit (see fig. 2). Fix UM to the range hood according
to the output direction of the wanted air (see fig. 3).
2) Fix the safety chains to the ceiling using the provided screws and wedges
(see fig. 4).
3) Lift the range hood near to the false ceiling: connect the UM (MU) motor
outlet to the air discharge duct using a flexible pipe. Carry out electric con-
nection only after having disconnected the electric power supply powering
the range hood. Introduce the safety chains inside the made holes in the
upper part of the range hood (fig. 5).
4) Place the hood in the false ceiling, which has been previously reinforced.
When opened, hooks G hold temporarily the hood to the false ceiling.
Fasten all screws (B) by rotating them clockwise, so to open the hooks and
block the hood on the panel of the false ceiling.
To remove the hood from the false ceiling, unfasten screws B by rotating
them counter-clockwise, paying attention to hold the hood appropriately
to prevent it from falling. Fix the chain to the hood by using the provided
screws and remove the exceeding links. Ensure the hood is fixed properly
to the false ceiling (see fig. 5).
5) Allocate the metallic filters and the AP panel again.
Remote motor positioned in a technical compartment protec-
ted against atmospheric agents inside the residence: define the
type of output
- Rectangular output of 90x220 mm (fig. 6). Remove the FC flange fixed on
the range hood and assemble the flange for FR rectangular pipe (optional).
Install UM in the wanted position.
- Circular output diam 150 mm (fig 7). Verify that the FC flange is assembled
on the range hood. Install UM in the wanted position.
- In case of installation with remote motor, connect the range hood body to
the electrical system earthing (after having verified its functioning), by me-
ans of suitable cable. It is advised to comply with the current regulations
on electrical safety of the systems and of the devices for the earthing of the
equipment.
- Follow the instruction in previous paragraph, starting from point 2.
- Comply with current regulations for air discharge.
Recirculation version:
in this version, the cooking fumes are reintroduced into the environment after
having been purified by the carbon filters (see sec. H). In this version, UM
must be assembled on the range hood and its output must be connected to
a filter that discharges towards the kitchen interior environment, set on the
false ceiling or in other suitable position.