COMPACT 1.6
Control Panel
4
1.- On/off: Switching the unit On - Off and mode selection F4 / F0 / F1 / F2 / F6
2.- Temperature selector (15/27 ºC - 59/80 ºF), Remote control programming and
degrees Fahrenheit and Airspeed: Environmental temperature control and centri-
fugal blower speed (speeds 1 to 5) in manual mode only.
3.- Display: Screen showing the function selected and the status of the equipment.
4.- Led On - Indicate the compressor functioning.
• On connection, the equipment checks the leds and
turns off.
Special display messages (please see failure Diagnosis):
: "Technical Control" Low battery (the unit will beep for a few moments and go off).
EO :
Poor contact of the return air sensor cables, or return air sensor faulty.
E6 :
Poor anti-freeze sensor cable contact, or anti-freeze sensor faulty.
Turning the Equipment On
To turn the Compact 1.6 unit on, press the On/Off key
on the F4 Function (Automatic Function).
To change the function, hold down the On/Off key
displayed, release the key on obtaining the desired function.
3
2
- 1
appears on the screen and
. The unit will always start up
. The different functions will be
9
EN
1