TEMPERATURE
1. After power on ,the indoor temperature will display automatically,
it will update reading each 30 seconds and start to receive outdoor
signal which lasts for max 3 minutes.
2. Indoor temperature display range:-10°C~ 50.0°C(14°F~ 122°F);
for temperature lower than -10°C,the reading will be :"LL.L";
for temperature higher than +50°C,the reading will be :"HH.H".
3. Outdoor temperature display range :-40°C~60°C(-40°F~140°F);
for temperature lower than -40°C,the reading will be :"LL.L";
for temperature higher than +60°C,the reading will be :"HH.H".
4. Arrow indication for temperature changes:
will display when temperature changes less than 1°C
within one hour or compared with last reading.
will display when the reading increase by 1°C within one hour
or compared with last reading.
will display when the reading decrease by 1°C within one hour
or compared with last reading.
5. Accuracy: For temperature between 0°C~50°C,the accuracy is ± 1°C,
if out of this range the accuracy will be ± 2°C; Temperature resolution
is 0.1°C(0.1°F).
6. Press "SET " button to select the temperature unit °C/°F
(Refer to Manual Settings point 6).
TEMPERATURE ALERTS
Check and Turn ON/OFF Alerts
1. When in time display mode, press "ALERTS " button to check
temperature alerts .
2. Press and release the "ALERTS" button to check alerts by the order:
Outdoor High Temperature Alert→ Outdoor Low Temperature
Alert→ Indoor High Temperature Alert →Indoor Low
Temperature Alert→ Exit.