Service Parts - Broan ULTRA SILENT QT90E Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL GRILLE
6. Finish ceiling.
Install ceiling material. Cut out around housing.
7. Attach grille
to housing.
Squeeze grille
springs and insert
them into slots on
each side of hous-
ing.
8. Push grille
against
ceiling.

SERVICE PARTS

Key No.
Part No.
1
97016466
Housing
2
97016449
Duct Connector-4"
3
98010102
Wiring Plate
4
99170245
Screw, #8-18 X .375
5
97018010
Wire Panel/Harness Assembly
6
97017854
Blower Assembly
7
97017642
Grille Assembly
(includes key no. 8)
8
99140199
Grille Spring (2 req'd)
9
97018014
Spacer (2 supplied)
10
99420665
Thumbscrew, #8-18 x .375
Order service parts by "Part No." - not by "Key No."
All manuals and user guides at all-guides.com
Description
Replacement parts can
be ordered on our web-
site. Please visit us at
www.broan.com
SERVICE NOTE
To remove Blower
Assembly:
Unplug motor.
Remove
thumbscrew (10)
from motor plate
flange.
Find the single TAB
on the motor plate
(located next to the
receptacle).
Push up near motor
plate tab while
pushing out on side
of housing. Or insert
a straight-blade
screwdriver into slot
in housing (next to
tab) and
twist screwdriver.
MODEL QT90E
Page 4
99044626B

Publicidad

Tabla de contenido
loading

Tabla de contenido