Page 13
Troubleshooting
Symptom: The fan does not run.
• Check for an open fuse or circuit breaker in the building's
service panel.
• Check that the two (2) plug-in connections for the Motor
and the Control are seated firmly in place.
• Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically.
• Check that the Blower Wheel is firmly attached to the
Motor shaft and both spin freely.
Symptom: The fan seems noisy.
• Check that the back draft damper in the fan's Duct
Connector pivots freely. Screws used to attach the duct to
the Duct Connector may be preventing the damper from
opening.
• Check that the back draft damper in the wall or roof cap
pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris..
XB50L
Service Parts
6
7
Order replacement
parts by Part No.,
not by Key No.
Key No. Part No.
Description
1
97018349
Mounting Frame
2
97018721
Knockout Plate & Screws
3
97018382
Housing
4
97018473
Wiring Panel/Harness Assembly
5
97019402
Control Assembly & Motor (XB50L)
97019401
Control Assembly & Motor (XB80L)
97018763
Control Assembly & Motor (XB110L)
6
97018331
Duct Connector - 6"
7
99111513
6" to 4" Reducer (models XB50L and XB80L only)
8
99020301
Blower Wheel
9
97018768
Scroll Assembly (XB110L)
97019371
Scroll Assembly (XB50L, XB80L)
10
97018871
Grille Assembly (includes 11, 12)
11
99140208
Grille Spring (2 req'd)
12
99111399
Lens
13
99271381
Bulb, GU24 18W 3500K Fluorescent (2 req'd)
XB80L
XB110L Installation Guide
n
n
1
3
4
8
9
12
2
5
10
11