Caution!
Note the polarity.
The same wire colour must be in the same wire guide for both union nuts.
☞
When tightening the union nut, the electrical contact and tension relief are created
automatically.
Special seals act as protection from dust and water.
12.19 Connect the wires between the electronic module, the solenoid valve cartridge and
the piezo button.
A: Solenoid valve cartridge for mixed water
B: Solenoid valve cartridge for thermal disinfection bypass (optional)
C:0-10 V analogue output
D:Cold water temperature sensor (optional)
E: Hot-water temperature sensor (optional)
F: Sensor connection 2/3
G:Piezo button
H:Electrical T-distributor system cable (power)
K: Electronic module
12.20 Only for water connection from the rear: Prioritise work steps 12.22 to 12.24.
12.21 Mount the shower panel on the suspension rail and screw tight.
12.22 Establish the water connections.
12.23 Open the water volume regulators using an Allen key.
a: closed
b: open
12.24 Check the water connections for leaks.
13. Function
Trigger the flow of water
13.1 Press the piezo button.
• The water will flow.
• The water stops automatically following the set flow time or if you press the piezo
button once more.
Flow duration
The flow duration is factory-set to 30 seconds. You can adjust the flow time in
0.1 second increments from
1 to 6,500 seconds.
Temperature selection
- 8 -