Filling In Detergents - Kärcher SB MU Manual Del Usuario

Ocultar thumbs Ver también para SB MU:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

If the ambient temperature exceeds the set
value, the foam is set to a wetter formula in
order to counteract surface drying.
If the ambient temperature falls below the
set value by the hysteresis, the drier foam
quality is selected again.
Setting the dosing pumps
Adjustable between 1% and 100%.
Off = pulse off (0%)
The adjustment of the dosing pumps is ex-
ecuted as described in the beginning of this
chapter (see "Adjusting parameter with one
variable").
System
This menu item is not used.
External thermostat
The external thermostat switches on the
following anti-frost equipment depending
on the external temperature:
below +3°C:
Hose heater dry foam (option)
below +1°C:
Submersible pump antifreeze
Note
The switching temperature of the exterior
thermostat can be set by customer service.

Filling in detergents

Provide detergent
Warning!
If the tank of the cleaning agent is empty,
the high pressure pump will suck air, and
can be damage. Check the cleaning agent
tank regularly.
Danger
There is a danger because of dangerous to
your health materials. All KÄRCHER clean-
ing agents to contain safety, and applica-
tion notices. Notices concerning the
application must be read and obeyed.
There listed protection clothing/protection
kit must be wear.
Only use KÄRCHER-approved detergents.
1 Detergent canister
High pressure wash / wet foam
Hot wax
Foam wash
Dirt removal
Top care
1 Detergent canister
Rim cleaner
1 Detergent canister
Polish
Foam
RM
RM
RM
RM
806
812
837
820
9
-
EN
This system uses undiluted detergents.
The detergent suction hoses are colour
coded:
yellow
orange
red
light green
dark green
blue
white
Note
The colour coding of the suction hoses is
also explained on the frame of the pump
module.
 Hang in the detergent hose into the de-
tergent can.
Bleed dosing pump.
1 Ventilation lever
2 Ventilation button
3 Adjustment knob dosing volume
The compressed air supply of the system
must be operating.
 Turn the ventilation lever in an anti-
clockwise direction until it stops.
 Set the dosing volume to 100%.
 Press the ventilation key until the deter-
gent emerges from the ventilation line
at the bottom of the dosing pump with-
out bubbles.
 Set the dosing volume to the required
value.
 Turn the ventilation lever in a clockwise
direction until it stops.
RM
RM
821
801
High pressure wash /
wet foam
Preservation
Hot wax
Foam Wash
Dirt Loosening
Top care
Rim cleaner
47

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1.070-002.0

Tabla de contenido