Kärcher SB MU Manual Del Usuario página 65

Ocultar thumbs Ver también para SB MU:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Display
Cause
F 096
Thermal motor protection switch of high pressure-pump washing
station 5 has tripped.
F 097
Oil level of high-pressure pump at washing station 5 too low
F 098
Electronics at washing station 5 defective.
F 100
No connection to remote control electronics at washing station 5
F 101
Fault at coin validator at washing station 5
F 102
F 110
No connection to pump electronics at washing station 6
F 111
Electronics outlets at washing station 6 overloaded
F 112
Current consumption of high-pressure pump at washing station 6 too
high
F 113
Current consumption of high-pressure pump at washing station 6 too
low
F 114
Contactor of high-pressure pump at washing station 6 jammed
F 115
Semiload valve at washing station 6 defective
F 116
Thermal motor protection switch of high pressure-pump washing
station 6 has tripped.
F 117
Oil level of high-pressure pump at washing station 6 too low
F 118
Electronics at washing station 6 defective.
F 120
No connection to remote control electronics at washing station 6
F 121
Fault at coin validator at washing station 6
F 122
F 130
No connection to pump electronics at washing station 7
F 131
Electronics outlets at washing station 7 overloaded
F 132
Current consumption of high-pressure pump at washing station 7 too
high
F 133
Current consumption of high-pressure pump at washing station 7 too
low
F 134
Contactor of high-pressure pump at washing station 7 jammed
F 135
Semiload valve at washing station 7 defective
F 136
Thermal motor protection switch of high pressure-pump washing
station 7 has tripped.
F 137
Oil level of high-pressure pump at washing station 7 too low
F 138
Electronics at washing station 7 defective.
F 140
No connection to remote control electronics at washing station 7
F 141
Fault at coin validator at washing station 7
F 142
F 150
No connection to pump electronics at washing station 8
F 151
Electronics outlets at washing station 8 overloaded
F 152
Current consumption of high-pressure pump at washing station 8 too
high
F 153
Current consumption of high-pressure pump at washing station 8 too
low
Remedy
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Refill oil, acknowledge the fault.
Call customer service.
Check the connector of the data cable with the
electronics of the remote control.
Call customer service.
Check the microswitch on the mechanical coin
acceptor, replace electronic coin acceptor
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
See "Faults on high pressure pumps"
Call customer service.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Refill oil, acknowledge the fault.
Call customer service.
Check the connector of the data cable with the
electronics of the remote control.
Call customer service.
Check the microswitch on the mechanical coin
acceptor, replace electronic coin acceptor
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
See "Faults on high pressure pumps"
Call customer service.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Refill oil, acknowledge the fault.
Call customer service.
Check the connector of the data cable with the
electronics of the remote control.
Call customer service.
Check the microswitch on the mechanical coin
acceptor, replace electronic coin acceptor
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
Acknowledge the fault. If the fault recurs, call cus-
tomer service.
See "Faults on high pressure pumps"
27
-
EN
65

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1.070-002.0

Tabla de contenido