Troubleshooting

8.2

Disposing of the device

If you wish to finally dispose of the device, take it to the nearest recycling
centre or return it to your specialist dealer who will be happy to take it back
for a small fee.
9
Troubleshooting
In the event of malfunction, please check the following:
Fault
The cooler does not
work.
The cooler does not
start up after a long
period of inactivity.
14
Possible cause
The cooler is not
properly connected to
the electricity supply.
The cooler is not
properly connected
to the gas.
The cooler has not
been set up properly.
The cooler has not
been filled properly.
The refrigerant circuit
is defective.
Suggested remedy
Check if the voltage supply is in full
working order.
Check if all electrical contacts are in full
working order.
Check if the voltage supply corresponds to
the value on the type plate.
Check if the thermostat control is
switched on.
Check if several energy sources are
connected at the same time.
Check if the gas supply is in full
working order.
Check if the valve on the gas bottle is open.
Check if there is still gas in the bottle.
Check if several energy sources are
connected at the same time.
Hold the rotary switch down longer
when igniting.
Check if the device is horizontal.
Check if the ventilation of the device
is sufficient.
Check if warm food has been put into
the device.
Check if the cooling space has been
overfilled or packed too densely.
This can only be repaired by an authorised
customer services unit.
Disconnect the device from the energy
supply and turn the cooler upside down
and wait around five minutes.
Turn the cooler the right way up again
and switch it on again.
A-40