geberit 116.452.00.1 Instrucciones De Uso página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 28
Checking the generator unit control and charging the rechargeable battery
Checking the generator unit control and charging the rechargeable battery
Connect the power supply unit
plug (7) to the power supply
system.
All of the
LEDs on the battery
charger light
up briefly?
Yes
Pull the generator plug (11)
from the generator female
connector (9) and connect the
charging cable (1) with the
generator female connector (9).
Error LED (3)
continuously lights
up red?
No
Error LED (3)
flashes red?
No
Charging procedure starts.
LED 25% continuously
lights up green?
No
LED 25% flashes green.
12
No mains voltage or battery
charger is defective.
No
Rechargeable battery is
defective (totally discharged).
Yes
Generator unit control is
defective.
Yes
Sufficient energy in the
rechargeable battery.
Yes
Rechargeable battery does
not need to be charged.
Replace generator unit control.
Replace generator unit control.
Control is working.
Continue on the next page.

Publicidad

Tabla de contenido
loading

Tabla de contenido