Checking the lavatory tap and generator
Checking the lavatory tap and generator
Connect the power supply unit
plug (7) to the power supply
system.
All of the
LEDs on the battery
charger light up
briefly?
Yes
Pull the eco power adapter
cable (8) from the automatic tap
female connector (10) and
connect it with the automatic
tap test cable (5).
Green test LED (4)
flashes?
Yes
Automatic tap runs through the
automatic teach-in process
(duration approx. 45 s).
Water has flowed for
a few seconds?
Yes
Check whether the automatic
tap is running.
Test successful?
Yes
Automatic tap is working.
10
No mains voltage or battery
No
charger is defective.
Cable connection between
No
battery charger and eco power
adapter is interrupted.
Or
Automatic tap is defective.
Automatic tap is defective.
No
Automatic tap is defective.
No
Secure the cable connection or
replace the eco power adapter.
Replace the electronics module
of the automatic tap.
Check automatic tap.
- Solenoid valve
- Electronics module
Replace the electronics module
of the automatic tap.
Continue on the next page.