OPERATION
Feed a strip of brad nails into the magazine. Be sure
the nail heads are pointed upward, the tips are pointed
downward, and the tips rest against the bottom of the
magazine.
Push the magazine cover closed until it securely snaps
into place.
WARNING:
Use only the nails recommended for use with this
tool (refer to the Fastener Guide). The use of any
other nails can result in tool malfunction, leading
to serious injuries.
WARNING:
Never load nails with the workpiece contact or
trigger activated. Doing so could result in possible
serious personal injury.
USING THE SELECTAbLE TRIGGER
See Figures 6 - 7, page 18.
WARNING:
Never wedge or hold back the workpiece contact
mechanism during operation of the tool. Doing so
could result in possible serious injury.
This tool is shipped from the factory with a selectable trigger
set in the Single Sequential Actuation mode. The selectable
trigger can also be set for Contact Actuation mode.
SINGLE SEQUENTIAL ACTUATION MODE
Single sequential actuation provides the most accurate
fastener placement.
Disconnect the tool from the air supply.
Depress the trigger lever pivot pin.
Rotate the selector to Position A.
Release the trigger lever pivot pin.
WARNING:
The nailer will not function properly if the selector
is not securely seated in either position A or B.
Always assure the selector is seated properly
to avoid an unexpected fastener discharge and
possible serious personal injury.
Reconnect the tool to the air supply.
Grip the tool firmly to maintain control. Position the nose
of the tool onto the work surface.
Push the tool against the work surface to depress the
workpiece contact.
Squeeze the trigger to drive a fastener.
All manuals and user guides at all-guides.com
Allow the tool to recoil away from the work surface as the
Always remove your finger from the trigger when the
CONTACT ACTUATION MODE
Contact actuation allows very fast repetitive fastener place-
ment.
Disconnect the tool from the air supply.
Depress the trigger lever pivot pin.
Rotate the selector to Position B.
Release the trigger lever pivot pin.
NOTE: The trigger lever pivot pin is spring loaded and held
in position by locking tab to prevent movement during op-
eration.
Reconnect the tool to the air supply.
Grip the tool firmly to maintain control.
Squeeze and hold the trigger. Push the tool against the
Allow the tool to recoil away from the work surface as the
Always remove your finger from the trigger when the
NOTE: In Contact Actuation Mode, the tool may also be
operated by depressing the workpiece contact against the
surface and squeezing the trigger.
DRY-FIRE LOCKOUT
When the magazine is almost empty of nails, the dry-fire
lockout feature will not allow continued operation.
To resume operation, reload the tool with nails.
SETTING THE AIR PRESSURE
The amount of air pressure required will depend on the size
of the nail and the workpiece material.
Begin testing the depth of drive by driving a test nail into the
same type of workpiece material used for the actual job.
Drive a test nail with the air pressure set at 90-95 psi. Raise
or lower the air pressure to find the lowest setting that will
perform the job with consistent results.
11 – English
fastener is driven.
desired number of nails has been driven.
work surface to depress the workpiece contact and drive
a fastener.
fastener is driven.
desired number of nails has been driven.
WARNING:
During normal use the tool will recoil immediately
after driving a fastener. This is a normal function
of the tool. Do not attempt to prevent the recoil
by holding the nailer against the work. Restriction
to the recoil can result in a second fastener being
driven from the nailer. Grip the handle firmly, let
the tool do the work, and do not place second
hand on top of tool or near exhaust at any time.
Failure to heed this warning can result in serious
personal injury.