Juno Trac 12/25 LED-Compatible Transformers
SAVE THESE INSTRUCTIONS
MOUNTING INSTRUCTIONS
Pendant Stem Mount (TF60 STEM)
1. Remove HOUSING from MOUNTING PLATE assembly.
2. Attach MOUNTING PLATE assembly to JUNCTION BOX (not
included) with JUNCTION BOX SCREWS (not included).
3. Connect TRANSFORMER INPUT LEAD WIRES to 120V electrical
supply wires. Connect white to white and black to black. Connect
green GROUND WIRE in accordance with NEC requirements.
4. Route TRANSFORMER SECONDARY LEAD WIRES through
HOUSING. Dress wires and replace HOUSING onto MOUNTING
PLATE and secure.
5. Route TRANSFORMER SECONDARY LEAD WIRES through
PENDANT STEM (not included) and attach PENDANT STEM to
HOUSING. Secure PENDANT STEM in place using PENDANT
STEM SET SCREWS.
6. Fasten the pendant mounting kit to the TLR50 (not included)
mounting plate as shown.
7. Bend wires so they form a 90º angle towards the front of the
mounting plate as shown. Cut and strip the wires to length per
the plate markings.
8. Bend the wires slightly away from the plate and insert them into the
corresponding terminal block opening. Set-screws may have to be
loosened to allow wire to be inserted. (Note: terminal block is to be
positioned with the pointed screw opposite wire entry). Tighten the
(2) terminal block set-screws until snug to retain the wires.
9. Position the terminal block (with wires attached) so the terminal
block holes line up with the holes in the mounting plate. Fasten to
the mounting plate with the mounting screws.
10. Loosen the (2) set-screws on the open side of the terminal block
(enough to allow the buss-wire to enter the terminal block) and
loosen the pointed screw which fastens the connector to the trac.
11. Verify the trac has from 3/8"-7/16" of buss wire extending past
the end. Slide the connector so the mounting plate slides into the
channel in the top of the trac. Hold firmly together and tighten
the pointed screw until snug.
12. To make electrical connection to the buss, tighten the (2) set-screws
closest to the trac to 12 to 18 in-lb (1 to 1.5 ft-lb). Tighten the
set-screws retaining the transformer wires from the pendant kit to
12 to 18 in-lb.
13. Reinstall the cover by placing over terminal block assembly and
tightening the cover screw.
1300 S. Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • Visit us at www.acuitybrands.com/juno-trac
©2017 Acuity Brands Lighting, Inc
INSTALLATION INSTRUCTIONS
Rev 3/17
P6034
Transformer Input
Lead Wires (2)
Transformer
Secondary
Lead Wires (2)
Pendant Stem
Mounting Screws
Wires
Terminal Block
Cover
Junction Box
(not included)
Ground Wire
Mounting Plate
Junction Box Screws (2)
(not included)
Housing
Housing Screws (2)
Pendant Stem
Set Screws (2)
TLR50
Trac
Mounting Plate
Buss Wire
Pointed Screw
Set Screws
Cover Screw
4 of 4