Maintenance
SPECiFiCATiONS
Starting Wattage
........................
I 3,500 watts
Wattage
................................
8,000 watts
AC Load Current:
At 120Volts
...........................
66.6 Amps
At 240Volts
...........................
33.3 Amps
Phase .....................................
I-phase
Rated Frequency
...........................
60 Hertz
Fuel Tank Capacity .......................
7 U.S. gallons
Shipping Woght
.............................
198 Ibs.
GENERAL
HAINTENANCE
RECOHHENDATIONS
The Owner/Operator
is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly
stored.
NEVER
operate
a
damaged
or defective
generator.
NOTE:
Should you have questions
about
replacing
components
on your Troy-Bilt generator,
please call
I=888=61 I =6708
for assistance.
Engine
Plaintenanre
See engine operator's
manual for instructions.
i
A CAUTiO.
i
" Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and watei:
KEEP OUT OF REACH OF CHILDREN.
DON'T
POLLUTE.
CONSERVE
RESOURCES.
RETURN
USED OILTO
COLLECTION
CENTERS.
Generator
Haintenanre
Generator
maintenance
consists
of keeping the unit clean
and dry. Operate
and store the unit in a clean dry
environment
where
it will not be exposed
to excessive
dust, dirt, moisture
or any corrosive
vapors.
Cooling
air
slots in the generator
must not become
closed
with snow,
leaves or any other
foreign
material.
NOTE:
DO NOT
use a garden
hose to clean generator.
Water
can enter
engine fuel system
and cause problems.
In
addition,
if water
enters
generator
through
cooling air slots,
some of the water
will be retained
in voids and cracks of
the rotor
and stator
winding
insulation.Water
and dirt
buildup on the generator
internal
windings
will eventually
decrease
the insulation
resistance
of these
windings.
WARNING
WHEN
ADJUSTING
OR HAKING
REPAIRSTOYOUR
GENERATOR
" Disconnect
the spark
plug wire from the spark plug and place
the wire where
it cannot
contact
spark
plug.
WHEN
TESTING
FOR
ENGINE
SPARK
Use approved
spark plug teste_:
DO NOT check for spark with spark plug removed.
Battery
Haintenanre
Other
than float charging, described
elsewhere,
no
maintenance
is required
for the starting battery.
Keep the
battery
and terminals
clean and dry.
iMPORTANT:
Battery
charging
should be performed
in a
dry location,
such as inside a garage.
Generator
Cleaning
• Use a damp cloth to wipe exterior
surfaces
clean.
CAUTION
Q
Q
Q
DO NOT
expose
generator
to excessive
moisture,
dust, dirt,
or corrosive
vapors.
DO NOT
insert
any objects
through
cooling
slots.
Use a soft bristle brush to loosen
caked on dirt or oil.
Use a vacuum
cleaner
to pick up loose dirt and debris.
Use low pressure
air (not to exceed
25 psi) to blow
away dirt. Inspect
cooling air slots and opening
on
generator.These
openings
must be kept clean and
unobstructed.
O