2.7.

Relay digital outputs (DOxx)

The controller program allows managing up to four non-critical loads when we have electrical surplus. The four relays that enable
these loads are included in the box of the ecoSMART e-manager. The supply of each relay is independent, so that different working
voltages can be used in each of them. The following figure shows an example of the installation of the power supply of a relay.
POWER
SUPPLY
8
7
6
24 Vac
FBus
BMS2
Figure 2.8. Example of power supply connection to relays of the digital outputs
Each relay allows cutting the poles (line + neutral) with a capacity of 8A / 250Vac per pole. If the equipment to be controlled
exceeds this capacity it is necessary to install an external relay.
Pay particular attention to the maximum consumption allowed by the relays. If necessary use an intermediate relay to make the
connection.